Installing a clamp-on flow meter—what should you keep in mind?
With an ultrasonic flow meter featuring clamp-on transducers, the transducers are mounted on the outside of the pipe. You don’t need to cut the pipe, drain the system, or shut down operations. With a few simple preparations, you’ll have everything you need for reliable measurements.
Here, we'll go over the most important things to know before installation.
Choose a good measurement location
The tube must be completely filled with liquid where the sensors are located. Air can interfere with the ultrasonic signal, and turbulence can affect the measurement.
The sensors can be mounted on both horizontal and vertical pipes, although vertical mounting is preferred. Choose a location where the pipe remains completely filled with fluid, and follow the installation instructions for your model.
Make the flow straight
Pumps, valves, and pipe bends can cause uneven flow and turbulence. Therefore, the sensors must be placed on a straight section of the pipe, away from anything that disrupts the flow.
A common recommendation is at least 10 times the pipe diameter before the first sensor and 5 times the pipe diameter after the second sensor, measured in the direction of flow.
Shorter straight runs may work in certain applications, but this depends on the transducer model and the configuration of the piping system. Follow the instructions for your product.
Prepare the pipe surface
The surface where the sensors will be mounted must be clean and smooth. Remove any loose paint, rust, and dirt so that the sensors make good contact with the pipe.
Apply the included ultrasonic grease so that the entire contact surface is covered, following the product instructions. The grease helps the ultrasonic waves pass between the transducer and the pipe wall.
Install the sensors at the correct distance
The placement of the sensors and the distance between them are important for the measurement. Depending on the model, either a pre-assembled sensor unit or separate sensors are used, which are positioned according to the meter’s instructions.
The meter calculates the sensor distance based on the pipe specifications you enter. Therefore, please verify that the specifications match those of your pipe.
Install and secure the sensors according to the installation guide for your specific model.
Check the measurement
Once the sensors are installed, check that the meter is receiving a strong signal and displaying good signal quality.
The values you should check are listed in the product's quick start guide or manual.
If the measurement doesn't start, you can check the following:
- The tube is completely filled with liquid.
- The pipe specifications are listed correctly.
- The sensors are positioned correctly and at the correct distance.
- The pipe surface has been cleaned, and ultrasonic degreaser has been used.
- The measurement site has sufficient straight sections.